Usage instructions on ¾", 1" & 1¼" Mueller No-Blo service tees

Safety Stopper
Fig. 1

Preparation and Pre-Fitting

1. Prepare service tee by removing protective wrapping from the cap to below the branch.

NOTE: Be sure the service tee type is the type that utilizes the brass completion plug and that the threaded cap can be removed without any release of natural gas.

2. Remove protective cap to gain access to the brass plug. Check that the completion plug removal tool fits the completion plug (Fig. 1).

 

Mounting the Safe-T-Stopper®

Safe-T-Stopper
Fig. 2
muller
Fig. 3

1. Select the proper size threaded adapter for the service tee to be stopped or removed.

2. Loosen the completion plug with a properly sized open end wrench – Do not loosen too much as the plug could become disengaged from threads. The completion plug removal tool is not designed to break the plug loose.

3. Screw the threaded adapter onto service tee and tighten with bar wrench supplied (Fig. 2). Operator may select to mount the threaded adapter with or without the ball valve.

4. Thread ball valve onto service tee threaded adapter if not already completed (Fig. 3). Hand tight is sufficient. Valve can be left in the open position.


mueller
Fig. 4
 

Removing the Completion Plug

CAUTION: If at any point during these procedures there is any apparent release of gas or other product stop the procedure immediately, and take corrective action.

1. Thread completion plug removal tool onto ball valve (Fig. 4). Hand tight is sufficient. Apply a light film of grease to tool shaft to assist in shaft movement.

2. Close 1/8" bleeder valve on upper side of ball valve.

3. Lower completion plug removal tool and engage completion plug. Be sure the tool engages the completion plug properly and the retainer stem of the tool drops sufficiently to retain the plug (approximately ½").
 

mueller
Fig. 5

4. Try to tighten the plug slightly to confirm proper tool engagement with the completion plug.

5. Push down on the tool continually while turning the tool counter clockwise to unscrew the plug from the service tee. Do not allow the hydraulic force to push the tool upward while unthreading the completion plug. A slight ratchet effect will be felt and heard once the completion plug has disengaged from the threads inside the service tee. Slowly raise the plug removal tool until completely up and out of the valve.

6. Close ball valve and open 1/8" bleeder valve (Fig. 5).

7. Remove completion plug removal tool from valve, complete with completion plug.

NOTE: Once cap has been removed, DO NOT leave tool unattended. Place the lock-out plug on to tool if unattended. Follow company lock-out procedures.
 

 

natural gas
Fig. 6
muller
Fig. 7
Inserting the Expandable Plug

1. Place the appropriate size expandable plug onto the expandable plug tool shaft in the tighten position (right side while looking down tool shaft) (Fig. 6). Be sure the expandable plug is completely relaxed to ensure a loose fit inside the service tee.

2. Before mounting expandable plug setting tool onto valve, place tool along side of the valve to get a distance measurement from the bottom of the expandable plug to the top of the expandable plug tool housing. This will ensure the expandable plug is located directly on top of the main line and far enough below service tee branch.

NOTE: Be sure to fully retract the expander plug inside plug setting tool housing before mounting the tool onto the valve.

3. Thread expandable plug setting tool onto ball valve (Fig. 7). Hand - tight is sufficient. Apply a light film of grease onto the tool shaft to assist in shaft movement.

4. Close 1/8" bleeder valve and open ball valve.

5. Slowly lower expandable plug down into service tee until the plug contacts the top of the main line or to the predetermined depth measured in step 2 of "Inserting the Expandable Plug" section.

6. Turn the expandable plug tool handle clockwise while holding the tool shaft until tight.

7. Open service line riser valve and vent service line to a safe location.

8. Once service line has been vented to a safe location, press expandable plug tool shaft downward slightly while turning tool shaft clockwise approximately ¼" to disengage from the expandable plug.

9. Raise expandable plug setting tool shaft upward.

 

natural gas
Fig. 8

10. Open 1/8" bleeder valve on ball valve to confirm all pressure has been released from tool.

11. Remove Safe-T-Stopper® tool if service tee is to be removed. Do not remove Safe-T-Stopper® tool if service tee is to be put back into service.

NOTE: - If expandable plug were ever to become disengaged from tool, attach magnetic retrieval tool to the plug setting tool to retrieve disengaged plug. (Fig. 8).




 

mueller
Fig. 9

To Remove Service Tee

1. With Safe-T-Stopper® tool removed from service tee, measure the distance from the top of the tee to the top of the expander plug.

2. Mark service tee cut off location. Be sure to cut service tee off above the tension nut on the expander plug. Do not use high heat devices to cut off tee. This could cause excessive heat for the expandable plug to remain in place. Use hand cutter or other tools approved by company standards, to cut off tee, ensuring that excessive heat is not created.

3. Place properly sized tapered plug closing device into service tee stub above the expandable plug (Fig. 9).

4. Once correct tapered plug closing device is set in place, tap the plug into place with a hammer and back-weld entire circumference onto service tee stub.

5. Operators may select an alternate stub closing device as approved by the company standards (eg. Threaded stub and threaded cap).

Mueller Natural Gas Service Tee Remover

Parts List

Ball Valve
Ball Valve
 
All Sizes - MSTS1005

Tool Shaft Housing
Tool Shaft Housing

 
All Sizes - MSTS1007

Removal Tool Shaft
Removal Tool Shaft
 
All Sizes - MSTS1008

Mueller Plug Removal Adapter
`Mueller No-BIo` Plug Remover Adapter
 
All Sizes - MSTS1021

Expandable Plug Setting Tool
Expandable Plug Setting Tool
 
All Sizes - MSTS1010

Mueller Expandable Plug
`Mueller No-BIo` Shorty Expandable Plug

 
Short: 3/4" - MSTS1022A
Short: 1" - MSTS1022B
Short: 1 1/4" - MSTS1022C
Long: 3/4" - MSTS1022D
Long: 1" - MSTS1022E
Long: 1 1/4" - MSTS1022F

Mueller Taper Plug
`Mueller No-BIo` Tapered Weld Plug

 
3/4"   - MSTS1023A
1"       - MSTS1023B
1 1/4" - MSTS1023C



Lock Out Plug
Lockout Plug

 
All Sizes - MSTS1014

Mueller Pipe to Valve Adapter
`Mueller No-BIo` Pipe To Valve Adapter

 
3/4"   - MSTS1020A
1"       - MSTS1020B
1 1/4" - MSTS1020C


Magnet
Magnet

 
All Sizes - MSTS1015B

Bleeder Valve
1/8" Bleeder Valve

 
All Sizes - MSTS1017

Ball Valve
Ball

 
All Sizes - MSTS1019

O Ring
O-Ring

 
All Sizes - MSTS1024